Fire Rated Servery Shutters

Fire Shutters for Doorways – Rigid Structures

From only £1,825.00 Ex VAT (£2,190.00 inc VAT)
(Based on 1000mm x 1000mm)

Get in Touch Today

Enquire Online or give us a Call

Key Product Features

Application

Doorways

Fire Rating

60-240 mins

Electric Operation

Single Phase - Tube or Industrial Motor

Max Width

8000mm (Depending on Height)

Max Height

3020mm (Depending on Width)

Box and Guides - Standard Finish

Galvanised

Curtain - Standard Finish

Galvanised

Lead Times

15-20 working days

Fire Shutters for Doorways – Rigid Structures

Our Fire Shutters for Doorways (Rigid Structures) are fully tested and certified for installation onto masonry, concrete, and protected structural steel supporting constructions. This makes them the ideal solution for corridors, fire escape routes, storage rooms, kitchens, commercial units, and any doorway where the surrounding structure is a solid, non-flexible substrate.

Designed only for openings when the shutter goes down to the floor.  This system has been independently tested specifically as a doorway installation on rigid construction. This provides guaranteed acceptance by Building Control, Fire Officers, and Approved Inspectors, ensuring full compliance with all relevant fire-safety standards.

The product is available with a 60-minute (E60), 90minute (E90), 120minute (E120) and 240minute (E240) fire integrity rating, allowing you to meet the fire strategy requirements of most commercial and public buildings.

Key benefits

  •  Tested and certified as a doorway opening, closing down to floor level,
  • Approved for Rigid wall type - Concrete, Masonry and Protected Structural Steel
  • Available with 60-minute (E60), 90minute (E90), 120minute (E120) and 240minute (E240) fire integrity rating.
  • Integrates with building fire alarm and detection systems for automatic closure.
     

Where it is used

Typical applications include:

  • School and college Corridors
  • Restaurant and café
  • Commercial kitchen hatches
  • Healthcare and hospitality storage rooms
     

Fire ratings and sizes


E60-240 – Up to 240-minute fire integrity

  • Tube motor (size range limited)
  • Industrial motor up to approx. 8000 mm W × 7000 mm H clear opening
  • Warrington Test Report – 404452

 

Tested / classified to:

  • BS EN 1634‑1 – Fire resistance testing of doors and shutters
  • BS EN 15269‑10
  • EN 13501‑2 – Fire classification of construction products
  • CE marked to BS EN 16034

 

Suitable wall types (Rigid Structures)

Designed for Rigid supporting constructions such as:

  • Concrete and Masonry -
    • Min Density 1600kgsm2
    • 102.5mm thick
       
  • Protected Structural Steel

    • Structural Steel Section Factor (A/V): Must be <230 m⁻¹.   
    • Box Section - Min. 60mm x 120mm x 5mm Rectangular hollow section (RHS)
    • MUST be protected on all 4 Sides to the fire rating of the shutter.
      • EN13381-4 - Passive - Fire Boarded
      • EN13381-8 - Reactive - Intumescent Paint

    For detailed requirements see our Fire Shutter Substrate Guide.

     

Landing surfaces

The shutter must close onto a compliant landing surface to maintain fire integrity. Typical options include:

  • Masonry or concrete
  • Class A1 non‑combustible substrate (EN 13501)
     

Controls & Safety Features

Every Servery Fire Shutter includes:

  • Fire Control Panel – standard or staged descent
  • Audio-Visual Warning – mandatory for serveries
  • Battery Backup Unit – ensures automatic closure under power loss
  • Integration with fire alarm or independent detectors
  • Emergency escape options where required

    For more details see our Fire Shutter Controls Guide


 

Information

Key Features – Fire Shutter for Doorways (Rigid Structure)
 

Certified for Rigid Supporting Walls

  • Specifically tested and approved for Rigid wall constructions - Masonry, Concrete and Structural Steel
  • Fully compliant with Building Control requirements for serveries

Independently Tested as a Doorway Opening

  • Certified for installation to close at floor level, ensuring full acceptance by Fire Officers.
  • Provides reliable fire compartmentation for doorways, full height serveries and corridors.

60 to 240 Minutes Fire Integrity

  • Available with E60 (60-minute),E90 (90-minute), E120 (120-minute) and E240 (240-minute)  fire ratings.
  • Tested to BS EN 1634-1, BS EN 15269-10, and classified to EN 13501-2.
  • CE Marked to BS EN 16034 for assured compliance.

Flexible Motor Options

  • Tube motor available for compact or smaller openings.
  • Industrial motor options available for larger openings up to 8000mm × 2400mm.

Designed for Masonry, Concrete and Structural Steel

  • Concrete and Masonry - Min Density 1600kgsm2 - 102.5mm thick
  • Structural Steel Section Factor (A/V): Must be <230 m⁻¹.  MUST be protected on all 4 Sides to the fire rating of the shutter.

Compatible Landing Surface Options

Closes onto a compliant non-combustible surface to maintain fire integrity, such as:

  • Masonry or concrete floor
  • Class A1 substrates

Integrated Fire Safety Controls

  • Comes with a Fire Control Panel (standard or staged descent).
  • Audio-Visual Warning system included—mandatory for serveries.
  • Battery Backup Unit ensures closure during power failure.
  • Seamless integration with the building’s fire alarm, smoke detectors, or heat detectors.
Electrical Requirements

This video explains what is required in regards to the Power Supply and Fire Alarm Interface for Tube Motor Fire Shutters.

Need more information?

Speak to one of our specialist advisors for more information about this product.